USER’S MANUAL
Electronaut M63 Vacuum Tube Microphone/Instrument Preamplifier
9
E L E C T R O N A U T C O M P A N Y
Helvetica neue condensed black
tracked like crazy, like 400 or something.
Usual logo is without concentric circles.
Website has the concentric circles.
Instrument input: The instrument jack is a locking quarter-inch connector used for connecting unbalanced
instrument cables to the M63. The input impedance of the instrument input jack is approximately one million
ohms. (1 MΩ)
TRIM
Controls
POLARITY
Switches
48V
Switches
Input Mode Select
Switch
ATTENUATE
Controls
VU Meters
INSTRUMENT
Jacks
POWER
switch
Input Mode Select
Switch
Pilot Lamp
Figure 2
Rear Panel
INPUT XLR connectors: The Input XLR connectors provide balanced inputs for microphones with an input
impedance of approximately 1800 ohms. As is consistent with modern standards, pin 1 is connected to the
chassis ground, pin 2 is for the positive phase of the signal, and pin 3 is for the negative phase of the signal.
OUTPUT XLR connectors: The Output XLR connectors provide a balanced, line-level output sufficient to drive
long cables and/or equipment with 600 ohm inputs, however the M63 will perform best when driving a higher
load impedance, such as a typical, modern 20 kΩ bridging input.